Getting down to earth megger pdf

In this method, four smallsized electrodes are driven into the earth at the same depth and equal distance apart in a straight line and a measurement is taken. Fourterminal earthground resistance and soil resistivity. Getting to know the mto product overview 300330 the megger transformer ohmmeter is a lineoperated, fieldportable instrument designed specifically to measure the dc resistance of all types of magnetic windings safely and accurately. The empirical relation as below gives the recommended minimum value for ir, its unit being mega ohm m. Hi friends, in this article, i am going to describe the earth tester working principle and method of earth resistance measurement by it. Megger working principle types history uses of megger. The return lead senses the current that is being carried by the device under test and compares it to the voltage being applied to calculate a resistance. The megger det family of test instruments offers a unique solution to the measurement of earth or ground electrode rod resistance and soil resistivity.

A practical guide to earth resistance testing pdf free download. Megger det23 digital ground resistance tester manual pdf. Getting down to earth 11 added salt percent by weight of moisture resistivity, ohmcm 0. Getting down to earth 9 8 getting down to earth equipment can also be damaged similarly by overvoltages caused by highresistance ground systems. The complete guide to electrical insulation testing. The megger det3td ground tester features a large selector switch makes selection of 2 pole or 3 pole test easy with gloved hands. We would be pleased to have a representative call on you to discuss your application. Suitable applications where there is doubt about a particular application, reference should be made to the advice and guidance contained in the publication, getting down to earth which is available from megger, part number 21500 072.

It was dr george tagg who pioneered earth testing at megger, and since megger has been at the forefront of innovative development and design. Instruction manual for transformer ohmmeter dc winding. Det62d threeterminal ground resistance tester det62d. Page there is an inherent safety problem in earth resistance. The det23 automatic earth test instrument is designed to measure earth electrode resistance and soil resistivity, with highly accurate results. A megger should be used the same way that a hipot or a power factor set would be used with the red positive lead being the hot and the black negative lead being the return.

Please refer to meggers booklet getting down to earth for further information. Voltage source ammeter 17 basic test methods for earth resistance megger instruments for earthresistance tests in clude. A digital display to show ir value in digital form. All of the new megger earth testers can perform this test and unlike some instruments, no external linking on the instrument is required. But the advantage of the earth that is, the planet itself, or the immediate portion of it is simply that there is so much of it. The megger insulation tester is essentially a highrange resistance meter ohmmeter with a builtin directcurrent generator.

Function up scroll down enter ir port on off 00k 0 0m g v 0g t 00g t k m 00m m 000v 500v 2500v to ground 5 k, 5 w resistor insulation step voltage test figure 37. Timeresistance testing method this method is fairly independent of temperature and often. How to test three phase ac motors learning electrical. It is stiff near the zero end of the coil and becomes very weak near the infinity end of the spring. Meggers det4tc2 is a portable, lightweight instrument used for easy measurements of earthing. Convert the 4 ft to centimeters to obtain a in the formula. A practical guide to earth resistance testing the word megger is a registered trademark.

Factors influencing requirements for a good grounding system in an industrial plant or other facility that requires a grounding system, one or more of the following must be carefully considered see fig. Earth testing kits including suitable test spikes and leads and a book describing several testing techniques entitled getting down to earth are also available. In other words, if the distance a between the electrodes is 4 ft, you obtain the average earth resistivity to a depth of 4 ft as follows. These days, megger offers topend systems for design and soil surveys as well as tough, easytouse testers for field engineers. The spring compresses the low resistance portion and opens the high resistance of the spring, which is the. Getting down to earth a practical guide to earth resistance testing earth testing and resistivity measuring requires sensitive equipment and sophisticated calculations. Megger clamp on ground testing guide pdf instrumart. Megger leads are connected to lv bushing studs and transformer tank earth point to measure insulation resistance ir value in between the lv windings and earth.

For a three phase motor, insulation resistance is usually measured between each motor winding or phase and between each motor phase and motor frame earth using an insulation tester or megger. D e t 3 2 digital earth tester test equipment depot. Fault current from a grounded electrical system can be dissipated effectively once it has cleared the immediate hurdle of transferring from the electrode into the surrounding soil and to infinite earth. The megger insulation tester is a small, portable instrument that gives you a direct reading of insulation resistance in ohms or megohms. Alternatively visit the megger earth testing website. Please refer to meggers booklet getting down to earth for further information on fall of potential tests and soil resistivity tests. The simplest and somewhat misleading idea of a good ground for an electrical system is a section of iron pipe driven into the earth with a wire conductor connected from the pipe to the electrical circuit figure 1 a practical guide to earth resistance testing megger on photo. A practical guide to earth resistance testing getting down to earth. If the resistance of the insulation is high, the pointer of the moving coil deflects towards the infinity, and if it is low, then the pointer indicates zero resistance. This guide makes these processes easier to understand for both large and small ground systems, with detailed studies of various relevant testing methods.

From years of experience in supplying instruments for the tests involved, megger can provide advice to help you make specific tests. Troubleshooting with insulation resistance test instruments. Bureau of standards now nist developed the theory behind this test in 1915 see reference pg. Getting down to earth is available, covering many other test techniques. The instrument is suitable for the testing of earth electrodes and measuring earth resistivity. Guide to clampon ground testing 3 clampon testing versus fall of potential testing fall of potential testing as mentioned, clampon, or stakeless, ground testing is a relatively. The result will cause either be the clamp low symbol appearing or an unexpectedly high reading. The device is being used since 1889, popularity raised during 1920s since the long back device is same in its uses and purpose of testing, few real improvements appeared in recent years with its design and quality of tester. D e t 3 2 digital earth tester description the megger det32 digital earth tester is a compact instrument designed to measure earth electrode resistance and soil resistivity. Det3td digital ground tester det3td digital ground tester. These days, megger offers topend systems for design and soil surveys as well as tough, easy to use testers for field engineers. Fourterminal earth ground resistance and soil resistivity.

The megger det14c and det24c ground resistance clamp testers represent a new generation of earth ground clampon resistance testers. The simplest and somewhat misleading idea of a good ground for an electrical system is a section of iron pipe driven into the earth with a wire conductor connected from the pipe to the electrical circuit figure 1. The megger det3td design makes the fitting of shorting links to perform 2 pole tests a thing of the past. Megger has published a book titled getting down to earth, a practical guide to earth resistance testing. Digital ground testers det4td2 and det4tr2 digital ground. The det23 can be used on large or more complex earth systems. Switches use to select electrical parameters ranges. Earth tester working principle your electrical guide. The family has seven variants supporting 2, 3 and 4wire measurements. The megger det14c and det24c ground resistance clamp testers represent a new generation of earthground clampon resistance testers.

This method is the most commonly used for measuring soil resistivity, which is important for designing electrical grounding systems. It is powered by an internal rechargeable battery which has a long usage period. Insulation resistance failure of an electric motor is one of the first signs that the motor is about to fail. Getting down to earth a megger guide to earth testing 21500072 ordering information electrical specifications ingress protection. It can be used to test in accordance with bs 7430 earthing, bsen62305.

Buy megger det3td earth ground resistance tester ireland. The det23 can be used on large or more complex earth systems, which include communications earth systems and difficult test environments. The det3ta provides 2 and 3wire measurements and offers an analogue display. The resistance of the earth can be measured with the help of megger earth tester or earth megger.

Fourterminal earthground resistance and soil resistivity tester. The det3tc will perform the traditional 3pole measurements like other earth testers. The megger is the instrument uses for measuring the resistance of the insulation. If you are unclear as to the meaning of sphere of influence, more information can be found in the megger publication getting down to earth, part number 21500 072. When the test switch is closed to the left, the current passing through the electrode under test from the testing generator and the voltage drop between the electrode under test and the potential spike are used as inputs to the log ratio computer. These instruments induce a test current into earth systems and measure ground resistance in multi ground installations without needing to disconnect the ground. Stakeless earth ground testing new det14c and det24c clamps getting around any challenge introduction megger has been designing, manufacturing and selling earth ground testers for well over 50 years. Earth testing det14c and det24c technical getting down to earth a practical guide to earth resistance testing. It is capable of performing 2, 3 and 4 point testing with variable frequency, attached rod technique via optional clamp sold separately, stakeless testing again via optional clamp, leakage current and ground noise voltage measurements. Thank you for purchasing the megger earth ground tester. The megger det3td ground tester is used to test for inherant dangers and potential cost implications of disconection of the earth spike. An insulation step voltage test is a test that creates electrical stress on internal insulation cracks to reveal aging or damage not found during other motor insulation tests. A practical guide to earth resistance testing megger on photo.

Two nos of wire leads for connecting megger with electrical external system to be tested. Electrical test equipment power station to plug megger. The resistance of the earth can be measured with the help of megger earth tester or earth megger earth tester working principle. Getting down to earth manual avtm25ta det62d threeterminal ground resistance tester ordering information test equipment depot 800. In megger, the combined action of both the voltage coils v 1 and v 2 are considered. Megger makes electrical test equipment to help you install, improve efficiency and extend the life of assets and cable networks at high, medium and low voltage. This technique is done with an earth resistance tester, often called a megger. Benefits simple to use, one touch operation auto switch off to save battery power rugged, weatherproof case large, clear lcd indicators show if reading may be. For good insulation, the resistance usually reads in the megohm range. Ensuring an effective earth system is essential in a telecommunications system, and megger is expert in earth testing having been there right from the start.

72 406 905 1241 1494 203 1203 1298 263 1142 622 570 125 591 634 1214 843 758 335 787 278 391 246 704 127 333 597 373 573 373 278 1354 845